35
* Nozzle Height Reading Adjustment *
Step 9
In manual mode, the control panel shows the nozzle heights of your sprayer,
for each boom section. The actual displayed heights may not be exactly the
same as your target height. The sensitivity setting determines the degree of
acceptable error between the two. See the description of SENSI in Section
5.4.2 for more information.
If your boom does not appear to be level, make sure it is not simply
sensitivity issue before proceeding with the suggestions below.
The nozzle offset for each sensor was calculated automatically in Step 6. If
your boom is not level at the proper height, you have two options – (1)
Repeat the installation process; or (2) Confirm sensor height readings
manually by following the procedure in Section 6.6.1.2.