35
Select the Next button (right arrow).
Select the Setup button.
Select Automatic Setup.
Acknowledge the warning.
Select the sprayer make and model from the lists.
Then select the Check button.
Read and acknowledge all of the precaution screens by
pressing the Check button. It is very important that you read
these precautions and follow them.
Follow the on screen directions by pressing the sprayer’s
manual boom movement buttons.
Level the boom at or near 35 inches (actual measurements can
be taken and entered later). Adjust the distance from the
nozzle to the ground directly beneath. Ensure you are over
bare, flat soil.
Using the Active Roll manual valve
overrides on the coils, level the center section.
Press
the Check button when finished.