9
6.2
Wing Sensor Installation
1.
The sensor bracket should be oriented forward (ahead of the boom).
2.
Mount the sensor brackets onto the boom half way between the tip and center of the
sprayer.
3.
Mount the NORAC ultrasonic sensor into the sensor bracket and run the sensor cable
either through hole in the back or through the sensor tube depending on the style of
bracket. Ensure the cable is clear of moving parts and will not be damaged during folding.
6.3
Low Profile Bracket Mounting
1.
Minimize the distance between the bolts to prevent bending the bracket and prevent the
bracket from loosening over time.
2.
Ensure the bracket is mounted tight against the bottom of the boom, minimizing the
distance between the boom structure and the angled flange.
Figure 11: Low Profile Bracket Mounting Guidelines
Figure 12: Low Profile Bracket Mounting
Front