5
3.2.2
Installation with 3-Way Coupler and Terminator Plug
1.
Remove the terminator plug (E20) from the existing 3-way coupler installed at the outer
sensor.
2.
Install the 3-way coupler (E10) at the inner sensor. Plug the terminator plug (E20) and the
sensor cable into the 3-way coupler.
3.
Connect the CANbus cable (C06) between the 3-way couplers.
Components shown in black are included in this kit.
Components shown in green are included in the bracket and hardware kit.
Components shown in blue are existing components.
Figure 7: Electrical Installation: 3-Way Coupler and Terminator Plug