6
4
Roll Sensor Removal
1.
Locate the two NORAC roll sensors (small rectangular box with a cable running from it).
There will be one mounted on the boom frame and one mounted on the intermediate
frame of the sprayer. Some machines will have a third roll sensor mounted on the chassis.
2.
Disconnect and remove all roll sensors. Refer to the installation manual for the specific
make/model of sprayer for roll sensor mounting locations. Installation manuals are available
at
www.norac.ca
.
3.
Insert the 6-pin plugs (P03) into the 8-way coupler where the roll sensors were connected.
Figure 8: NORAC Roll Sensor
Figure 9: NORAC 8-Way Coupler