Module Installation
6.1
Control Module
1.
Refer to
Figure 1
and
Figure 13
.
2.
Securely mount the control module (E01) inside the sprayer cab, using screws or cable ties.
3.
Connect the display terminal to the control module using the display cable. This cable must
be connected to the end of the control module with only one Deutsch connector.
4.
Connect the existing power cable to one of the two CANbus connectors on the other end
of the control module.
5.
Route cable C01 from the other CANbus connector towards the rear of the sprayer.