19
8.2
Valve Block Mounting
1.
Mount the valve block on the center section of the boom near the sprayer valve block, as
illustrated in
Figure 22
.
2.
Insert the threaded rod into the block and use a hex nut to hold the rod. The block holes
are 3/8” NC-1” deep. If bolts are used instead of the threaded rod, ensure the bolts thread
in at least 3/8”.
3.
Use the remaining hardware to secure the block to the sprayer.
4.
Cut off excess threaded rod, if necessary.
Figure 22: Valve Block Mounting
Ensure that the temperature probe from the Valve Module is attached to the
NORAC valve block as shown in the green square in Figure 22. This is NOT a
ground connection.