19
Sleep
The NorTronic
®
will go to
Sleep
if there has been
No activity
for the time set in
‘
Sleep After’
. During sleep,
none of the NorTronic
®
functions operate.
Sleep After ?
120
Sec
Press
or
to change value.
Press
or
to confirm and exit to
SETUP
.
Minimum =
10
,
Maximum =
300
. Default =
120
Set the time to
Never
(below 10)
to disable
SLEEP
.
Angle
Angle ?
Enabled
Press
or
to change setting.
Press
or
to confirm and exit to
SETUP
.
Enabled =
Display Torque & Angle.
Not Enabled =
Display Torque only
.
Auto Zero
Auto Zero ?
Enabled
Press
or
to change setting.
Press
or
to confirm and exit to
SETUP
.
Enabled = both the
TORQUE & ANGLE
readings will
Auto Zero
on
power up
or
resume from sleep
.
Not Enabled = the user must
press
the ZERO
button
to
reset
the
Torque display
to the current Torque
input and
Angle Display
to
“
0
”.
Active From
Threshold ?
9.0
%
Press
or
to change value.
Press
or
to confirm and exit to
SETUP
.
Minimum =
1.8 %
,
Maximum =
100.0 %.
Default =
9.0 %
Summary of Contents for NorTronic 43500