10
Hanger
The hanger can be used to suspend the PneuTorque
®
from a balancer.
Quick Tool Coupling
Air couplings supplied to allow quick tool connection and disconnection from the air hose.
SET UP INSTRUCTIONS
The PneuTorque
®
set up covers the following items:
1.
PneuTorque
®
Hanger
2. Connecting Air Supply
3.
Air
Lubrication
4.
Torque
Reaction
5. Clockwise / Counter-Clockwise Operation
6. Setting torque to tighten fastener
Please complete the set up in the order shown.
PneuTorque
®
Hanger
The PneuTorque
®
hanger (Figure 1-E) is designed to be used with a suitable balancer to provided
comfortable tool use. If not required the hanger can be removed.
Connecting Air Supply
WARNING: TO
AVOID
HAZARD FROM WHIPPING AIR HOSES MAKE ALL
CONNECTIONS TO THE TOOL BEFORE TURNING ON THE AIR SUPPLY.
Make sure all hoses are clean, in good condition and free from dirt / water.
Connect the tool air inlet hose (Figure 1-A) to the outlet side of the lubro control unit (Figure 1-B) (not
supplied), observing air flow direction arrows.
TIP:
On tools supplied with quick air couplings, fit the coupling plug
to the tool inlet and the coupling socket to air hose.
To connect, push couplings together.
To disconnect, pull back lock on socket coupling.
Connect the inlet side of the lubro control unit (Figure 1-B) to the air supply (Figure 1-C) using a minimum hose
size of 1/2” bore (12mm). Avoid using 1/2” bore hoses of longer than 5 meters from the supply to the pressure
regulator unit as this will reduce the performance of the tool.
Summary of Contents for PNEUTORQUE PTM series
Page 25: ...24 NOTES ...