SERVICE MANUAL
47
www.norcold.com
Fault Code - “Sr” with audible alarm
Possible Cause:
The main control board assembly (pow-
er board) detected an internal fault. This
fault can be displayed in any MODE.
NOR000706A
Does
problem
continue?
YES
Solved.
NO
Replace main control board assembly
(power board assembly).
To reset fault, power
refrigerator OFF and
then back ON.
Are gas
valve wires
plugged in?
NO
YES
Correct.
set
CODE
Flashes “Sr” with
an audible alarm.
Fault Code - “FL” “- -” with audible alarm
Possible Cause:
On the main control board assembly
(power board), the limit circuit is open.
Fault Code - “oP” “LI” with audible alarm
A flame is sensed at the burner when
there should be none present.
Possible Cause:
The gas valve is “mechanically” stuck
open. Therefore, the main control board
(power board) senses a flame is pres
-
ent at the burner when there should be
none
Replace gas train assembly
The gas valve is
“mechanically” stuck open.
NOR000709A
CODE
CODE
Alternately flashes “FL” and “--”
with an audible alarm.
CODE
CODE
Alternately flashes “oP” and “LI”
with an audible alarm.
TROUBLESHOOTING FLOWCHARTS - N7LX AND N8LX MODELS, cont’d.
NOR000804A
Replace the main control board
assembly (power board).
On the main control board
assembly (power board),
the limit circuit is open.