5 Parameters
BU 0500 EN-1516
101
Pos: 152 /Anleitungen/Elektronik/FU und Starter/5. Parameter/Parameterauflistung (P000 ...)/P200-P299/Parameter P203 – Motor Nennstrom @ 0\mod_1327588500455_388.docx @ 7930 @ @ 1
P203
Nominal motor current
(Nominal motor current)
S
P
0.1 ... 1000.0 A
{ see information }
The nominal motor current is a decisive parameter for the current vector control.
Information
Default setting
The default setting is dependent upon the FI nominal power and the setting in P200.
Pos: 153 /Anleitungen/Elektronik/FU und Starter/5. Parameter/Parameterauflistung (P000 ...)/P200-P299/Parameter P204 – Motor Nennspannung @ 0\mod_1327588687111_388.docx @ 7953 @ @ 1
P204
Nominal motor voltage
(Nominal motor voltage)
S
P
100 ... 800 V
{ see information }
The >Nominal voltage< matches the mains voltage to the motor voltage. In combination with the
nominal frequency, the voltage/frequency characteristic curve is produced.
Information
Default setting
The default setting is dependent upon the FI nominal power and the setting in P200.
Pos: 154 /Anleitungen/Elektronik/FU und Starter/5. Parameter/Parameterauflistung (P000 ...)/P200-P299/Parameter P205 – Motor Nennleistung @ 0\mod_1327588736705_388.docx @ 7976 @ @ 1
P205
Nominal motor power
(Nominal motor power)
P
0.00 ... 250.00 kW
{ see information }
The motor nominal power controls the motor set via P200.
Information
Default setting
The default setting is dependent upon the FI nominal power and the setting in P200.
Pos: 155 /Anleitungen/Elektronik/FU und Starter/5. Parameter/Parameterauflistung (P000 ...)/P200-P299/Parameter P206 – Motor cos phi @ 0\mod_1327588784877_388.docx @ 7999 @ @ 1
P206
Motor cos phi
(Motor cos
ϕ
)
S
P
0.50 ... 0.95
{ see information }
The motor cos
ϕ
is a decisive parameter for the current vector control.
Information
Default setting
The default setting is dependent upon the FI nominal power and the setting in P200.
Pos: 156 /Anleitungen/Elektronik/FU und Starter/5. Parameter/Parameterauflistung (P000 ...)/P200-P299/Parameter P207 – Motorschaltung @ 0\mod_1327589654065_388.docx @ 8022 @ @ 1
P207
Motor circuit
(Motor circuit)
S
P
0 ... 1
{ see information }
0 = star
1 = delta
The motor circuit is decisive for stator resistance measurement (P220) and therefore for current
vector control.
Information
Default setting
The default setting is dependent upon the FI nominal power and the setting in P200.
Pos: 157 /Anleitungen/Elektronik/FU und Starter/5. Parameter/Parameterauflistung (P000 ...)/P200-P299/Parameter P208 – Statorwiderstand @ 0\mod_1327589723457_388.docx @ 8045 @ @ 1
P208
Stator resistance
(Stator resistance
)
S
P
0.00 ... 300.00
W
{ see information }
Motor stator resistance
⇒
resistance of a phase winding with a DC motor.
Has a direct influence on the current control of the FI. Too high a value will lead to a possible
overcurrent; too low a value to a motor torque that is too low.
The parameter P220 can be used for simple measurement. Parameter P208 can be used for
manual setting or as information about the result of an automatic measurement.
NOTE:
For optimum functioning of the current vector control, the stator resistance must be automatically
measured by the FI.
Information
Default setting
The default setting is dependent upon the FI nominal power and the setting in P200.