6 Operating status messages
The device and technology units generate appropriate messages if they deviate from their normal
operating status. There is a differentiation between warning and error messages. If the device is in the
status "Start disabled", the reason for this can also be displayed.
The messages generated for the device are displayed in the corresponding array of parameter (
P700
).
The display of the messages for technology units is described in the respective additional instructions
and data sheets for the modules concerned.
Start disabled
If the device is in the status "Not Ready" or "Start Disabled", the reason for this is indicated in the third
array element of parameter (
P700
).
Display is only possible with the NORD CON software or the ParameterBox.
Warning messages
Warning messages are generated as soon as a defined limit is reached. However this does not cause
the frequency inverter to switch off. These messages can be displayed via the array-element [
-02
] in
parameter (
P700
) until either the reason for the warning is no longer present or the frequency inverter
has gone into a fault state with an error message.
Error messages
Errors cause the device to switch off, in order to prevent a device fault.
The following options are available to reset a fault (acknowledge):
• Switching the mains off and on again,
• By an appropriately programmed digital input (
P420
),
• By switching off the “enable” on the device (if no digital input is programmed for
acknowledgement),
• By Bus acknowledgement
Pos: 443 /Anleitungen/Elektronik/FU und Starter/6. Meldungen zum Betriebszustand/_Meldungen zum Betriebszustand_02 (Ergänzung FU) [SK 1x0E, SK 2xxE, SK 5xxE] @ 10\mod_1454426801196_388.docx @ 287852 @ @ 1
• By (
P506
), automatic error acknowledgement.
Pos: 444 /Anleitungen/Elektronik/FU und Starter/6. Meldungen zum Betriebszustand/Darstellung der Meldungen @ 3\mod_1361802708455_388.docx @ 59827 @ 2 @ 1
6.1 Display of messages
Pos: 445 /Anleitungen/Elektronik/FU und Starter/6. Meldungen zum Betriebszustand/Darstellung der Meldungen - LED Anzeigen @ 3\mod_1361796228478_388.docx @ 59694 @ 5 @ 1
LED displays
The status of the FI is indicted by integrated status LEDs, which are visible from the outside in the
state as delivered. According to the type of FI, this is a two-colour LED (DS = DeviceState) or two
single-colour LEDs (DS DeviceState and DE = DeviceError).
Meaning:
Green
indicates readiness and the present of mains voltage. In operation, the
level of overload at the FI output is shown with an increasingly rapid flashing
code.
Red
Signals the presence of an error by flashing according to the number
code of the error. This flashing code (e.g.: E003 = 3x flashing) indicates the
error groups.
Pos: 446 /Anleitungen/Elektronik/FU und Starter/6. Meldungen zum Betriebszustand/Darstellung der Meldungen - SimpleBox / ControlBox Anzeige [SK xxxE] @ 3\mod_1361801795294_388.docx @ 59802 @ 5 @ 1