SK 500E – Users Manual for Frequency Inverters
166
BU 0500 EN-3021
2.2
Overtemp. Brake r.ext
"Overtemperature of external
brake resistor "
Overtemperature via digital
input (P420 […])={13}
Warning: Temperature monitor (e.g. brake resistor) has
activated
•
Digital input is Low
Pos: 478 /Anleitungen/Elektronik/FU und Starter/6. Meldungen zum Betriebszustand/Störmeldungen (Auflistung)/Warnung C003 [SK 180E ... SK 5xxE] @ 2\mod_1347457006237_388.docx @ 47199 @ @ 1
C003
3.0
Overcurrent, I
2
t limit
Warning: Inverter: I
2
t limit has triggered, e.g. > 1.3 x I
n
for
60s (please also note P504)
• Continuous overload at FI output
3.1
Overcurrent, chopper I
2
t
Warning: I
2
t limit for the brake chopper has triggered, 1.3x
value attained for 60s (also note P554, if present, as well as
P555, P556, P557)
• Avoid overload of brake resistance
3.5
Torque current limit
Warning: Torque current limit reached
•
Check
(P112)
3.6
Current limit
Warning: Current limit reached
•
Check
(P536)
Pos: 479 /Anleitungen/Elektronik/FU und Starter/6. Meldungen zum Betriebszustand/Störmeldungen (Auflistung)/Warnung C004 [SK 180E ... SK 5xxE] @ 2\mod_1347457006705_388.docx @ 47224 @ @ 1
C004
4.1
Overcurrent measurement
"Overcurrent measurement"
Warning: pulse switch off is active
The limit for activation of pulse switch off (P537) has been
reached (only possible if P112 and P536 are switched off)
•
FI is overloaded
•
Drive sluggish, insufficiently sized
•
Ramps (P102/P103) too steep -> Increase ramp time
•
Check motor data (P201 … P209)
•
Switch off slip compensation (P212)
Pos: 480 /Anleitungen/Elektronik/FU und Starter/6. Meldungen zum Betriebszustand/Störmeldungen (Auflistung)/Warnung C008 [SK 180E ... SK 5xxE] @ 2\mod_1347457201563_388.docx @ 47249 @ @ 1
C008
8.0
Parameter loss
Warning:
One of the cyclically saved messages such
as
operating hours
or
enabling time
could not be
saved successfully.
The warning disappears as soon as saving can be
successfully performed.
Pos: 481 /Anleitungen/Elektronik/FU und Starter/6. Meldungen zum Betriebszustand/Störmeldungen (Auflistung)/Warnung C012 [SK 5xxE] @ 2\mod_1361539953134_388.docx @ 59296 @ @ 1
C012
12.1
Motor Limit / Customer
"Motor switch
-
off limit"
Warning: 80 % of the drive switch-off limit (P534 [-01]) has
been exceeded.
• Reduce load on motor
• Set higher value in (P534 [-01]).
12.2
Generator limit
"Generator
switch
-
off limit"
Warning: 80 % of the generator switch-off limit (P534 [-02])
has been reached.
• Reduce load on motor
• Set higher value in (P534 [-02]).
12.5
Load monitor
Warning due to overshooting or undershooting of
permissible load torques ((P525) … (P529)) for the time set
in (P528).
• Adjust load.
• Change limit values ((P525) ... (P527)).
• Increase delay time (P528).