Safety and usage instructions for electronic drive technology
(drive power controller, motor starter
1)
and field distributor)
(in accordance with: Low Voltage Directive 2006/95/EC (as of 20.04.2016: 2014/35/EU))
1. General
The devices may have live, bare, moving or rotating parts or hot
surfaces during operation, depending on their protection class.
Unauthorised removal of covers, improper use, incorrect installation or
operation causes a risk of serious personal injury or material damage.
Further information can be found in this documentation.
All transportation, installation commissioning and maintenance work
must be carried out by qualified personnel (compliant with IEC 364 or
CENELEC HD 384 or DIN VDE 0100 and IEC 664 or DIN VDE 0110
and national accident prevention regulations).
For the purposes of these basic safety instructions, qualified personnel
are persons who are familiar with the assembly, installation,
commissioning and operation of this product and who have the relevant
qualifications for their work.
2. Proper use in Europe
The devices are components intended for installation in electrical
systems or machines.
When the devices are installed in machines, they must not be started up
(i.e. commencement of use for intended purpose) until it has been
ensured that the machine meets the provisions of the EC Directive
2006/42/EC (Machinery Directive); EN 60204 must also be complied
with.
Starting up (i.e. commencement of use for intended purpose) is only
permitted if EMC directive (2004/108/EC (as of 20.04.2016:
2014/30/EU)) has been complied with.
CE-labelled devices fulfil the requirements of the Low Voltage Directive
2006/95/EC (as of 20.04.2016: 2014/35/EU). The stated harmonized
standards for the devices are used in the declaration of conformity.
Technical data and information for connection conditions can be found
on the rating plate and in the documentation, and must be complied
with.
The devices may only be used for safety functions which are described
and explicitly approved.
3. Transport, storage
Information regarding transport, storage and correct handling must be
complied with.
4. Installation
The installation and cooling of the equipment must be implemented
according to the regulations in the corresponding documentation.
The devices must be protected against impermissible loads.
Especially during transport and handling, components must not
be deformed and/or insulation distances must not be changed.
Touching of electronic components and contacts must be
avoided.
The devices contain electrostatically sensitive components,
which can be easily damaged by incorrect handling. Electrical
components must not be mechanically damaged or destroyed
(this may cause a health hazard!).
5. Electrical Connection
When working on live devices, the applicable national accident
prevention regulations must be complied with (e.g. BGV A3,
formerly VBG 4).
The electrical installation must be implemented according to the
applicable regulations (e.g. cable cross-section, fuses, earth
lead connections). Further instructions can be found in the
documentation.
Information regarding EMC-compliant installation (such as
shielding, earthing, location of filters and routing of cables) can
be found in the documentation for the devices. CE marked
devices must also comply with these instructions. Compliance
with the limit values specified in the EMC regulations is the
responsibility of the manufacturer of the system or machine.
6. Operation
Where necessary, systems in which the devices are installed
must be equipped with additional monitoring and protective
equipment according to the applicable safety requirements, e.g.
legislation concerning technical equipment, accident prevention
regulations, etc.
The parametrisation and configuration of the devices must be
selected so that no hazards can occur.
All covers must be kept closed during operation.
7. Maintenance and repairs
Live equipment components and power connections should not
be touched immediately after disconnecting the devices from
the power supply because of possible charged capacitors.
Observe the applicable information signs located on the device.
Further information can be found in this documentation.
These safety instructions must be kept in a safe place!
1) Direct starter, soft starter, reversing starter