NORDAC SK 750E Manual
116
Technical design subject to change
BU 0750 GB
Parameter
Setting value / Description / Note
Parameter
set
Available with option
P546
Func. bus-setpoint 1
P
immer sichtbar
0 ... 7
[ 1 ]
When the inverter is bus-controlled, this parameter allows for allocating a function to the transmitted
setpoint 1.
Note:
For more details see the applicable bus operating instructions.
0 =
Off
1 =
Setpoint freq. 16bit
2 =
Setpoint posn. 16bit
3 =
Setpoint posn. 32bit
4 =
PosiCon
5 =
Setp. posn. 16bit inc
6 =
Setp. posn. 32bit inc
7 =
BusIO In Bits 0-7
P547
Func. bus-setpoint 2
P
Always available
0 ... 20
[ 0 ]
When the inverter is bus-controlled, this parameter allows for allocating a function to the transmitted
setpoint 2.
Note:
For further details see the applicable bus operating instructions.
0 =
Off
1 =
Nominal frequency
2 =
Torque current limit
3 =
PID current freq.
4 =
Frequency addition
5 =
Frequency subtract.
6 =
Current limit
7 =
Maximum frequency
8 =
PID ltd.current.freq.
9 =
PID suprvsd.cur.freq
10 =
Servo-Mode Torque
11 =
Pre-tension Torque
12 =
PosiCon
3
control bits (only with
PosiCon
option)
13 =
Multiplication
14 =
Cur.val process ctrl
15 =
Nom.val process ctrl.
16 =
Add. Process control
17 =
Bus I/O In-bits 0-7
18 =
Cam control mode calculator
19 =
Set relais (P541)
20 =
Set analogue output (P542)
P548
Func. bus-setpoint 3
P
Always available
0 ... 20
[ 0 ]
When the inverter is bus-controlled, this parameter allows for allocating a function to the transmitted
setpoint 3. Only available if P546 3.
Note:
For further details see the applicable bus operating instructions.
This parameter is identical with P547.