5 Parameter
BU 0200 en-US-4920
217
Pos : 623 /Anleit ungen/El ektr onik /FU und St art er/5. Par ameter/ Par ameter auflist ung (P000 .. .)/P700- P799/Param et er P744 – Aus baust uf e [SK 1x 0E, SK 2xx E, SK 2xxE-FD S] @ 2\m od_1346932209541_14638. docx @ 43676 @ @ 1
P744
Configuration level
(configuration level)
0000 ... FFFF
(hex)
This parameter displays the devices integrated in the VFD. Display is in hexadecimal code
(Simple Box, bus system).
The display is in plain text when the Parameter box is used.
High byte:
Low byte:
Pos : 624 /Anleit ungen/El ektr onik /FU und St art er/5. Par ameter/ Par ameter auflist ung (P000 .. .)/P700- P799/Param et er P744 – Aus baust uf e_Teil 2/ 2 [ SK 2xxE] @ 9\mod_1448455671379_14638.docx @ 266930 @ @ 1
00
hex
Standard I/O
(SK 205E)
01
hex
STO
(SK 215E)
00
hex
No extension
02
hex
AS-i
(SK 225E)
01
hex
Encoder
03
hex
STO and AS-i
(SK 235E)
02
hex
Posicon
04
hex
Standard I/O
(SK 200E)
03
hex
---
05
hex
STO
(SK 210E)
06
hex
AS-i
(SK 220E)
07
hex
STO and AS-i
(SK 230E)
Pos : 625 /Anleit ungen/El ektr onik /FU und St art er/5. Par ameter/ Par ameter auflist ung (P000 .. .)/P700- P799/Param et er P747 – Umricht ers pannungsbereic h [SK 1x0E, SK 2xx E, SK 2x xE-FD S] @ 9\m od_1448457030116_14638. docx @ 266996 @ @ 1
P747
Inverter voltage range
(inverter voltage range)
0 ... 2
Indicates the line voltage range for which this device is specified.
0 =
100 – 120 V
1 =
200 – 240 V
2 =
380-480 V
Pos : 626 /Anleit ungen/El ektr onik /FU und St art er/5. Par ameter/ Par ameter auflist ung (P000 .. .)/P700- P799/Param et er P748 – Status CAN open [ SK 1x0E, SK 2xxE, SK 2xx E-FDS] @ 2\mod_1346932210180_14638. doc x @ 43700 @ @ 1
P748
Status CANopen
(CANopen status
(system bus statu))
0000 ... FFFF
(hex)
or
0 ... 65535
(dec)
Shows the status of the system bus.
Bit 0:
Bit 1:
Bit 2:
Bit 3:
Bit 4:
Bit 5:
Bit 6:
Bit 7:
Bit 8:
Bit 9:
Bit 10:
24 V bus supply voltage
CANbus in "Bus Warning" status
CANbus in "Bus Off" status
System bus
→
Bus module online (field bus module, e.g.: SK xU4-PBR)
System bus
→
Additional module 1 online (I/O - module, e.g.: SK xU4-IOE)
System bus
→
Additional module 2 online (I/O - module, e.g.: SK xU4-IOE)
The protocol of the CAN module is
0 =
CAN/
1 =
CANopen
Vacant
"Bootup Message" sent
CANopen NMT State
CANopen NMT State
CANopen NMT State
Bit 10
Bit 9
Stopped
Pre-operational
Operational
0
0
1
0
1
0