8 Additional information
BU 0200 en-US-4920
267
b) 400 V variable frequency drive
The following data is based on an output of 2.2 kW using a 230/400 V motor winding. 400/690 V
windings are used for 3 kW and higher.
They apply to IE1 and IE2 motors. It should be noted that these details may deviate slightly as motors
are subject to certain manufacturing tolerances. It is recommended that the resistance of the
connected motor is measured by the variable frequency drive (P208/P220).
Motor
(IE1)
SK …
Variable
Frequency
Drive
SK 2xxE-…
M
N
*
[Nm]
Parameterization data of variable frequency drive
F
N
[Hz]
n
N
[rpm]
I
N
[A]
U
N
[V]
P
N
[kW]
cos
ϕ
Y/
Δ
R
St
[
Ω
]
80S/4
550-340-A
3.82
50
1385
1.51
400
0.55
0.75
Y
15.79
80L/4
750-340-A
5.21
50
1395
2.03
400
0.75
0.75
Y
10.49
90S/4
111-340-A
7.53
50
1410
2.76
400
1.1
0.76
Y
6.41
90L/4
151-340-A
10.3
50
1390
3.53
400
1.5
0.78
Y
3.99
100L/4
221-340-A
14.6
50
1415
5.0
400
2.2
0.78
Y
2.78
100LA/4
301-340-A
20.2
50
1415
6.8
400
3.0
0.78
Δ
5.12
112M/4
401-340-A
26.4
50
1430
8.24
400
4.0
0.83
Δ
3.47
132S/4
551-340-A
36.5
50
1450
11.6
400
5.5
0.8
Δ
2.14
132M/4
751-340-A
49.6
50
1450
15.5
400
7.5
0.79
Δ
1.42
160M/4
112-340-A
72.2
50
1455
20.9
400
11.0
0.85
Δ
1.08
160L/4
152-340-A
98.1
50
1460
28.2
400
15.0
0.85
Δ
0.66
180MX/4
182-340-A
122
50
1460
35.4
400
18.5
0.83
Δ
0.46
180LX/4
222-340-A
145
50
1460
42.6
400
22.0
0.82
Δ
0.35
* at rated point
Motor
(IE2)
SK …
Variable
Frequency
Drive
SK 2xxE-…
M
N
*
[Nm]
Parameterization data of variable frequency drive
F
N
[Hz]
n
N
[rpm]
I
N
[A]
U
N
[V]
P
N
[kW]
cos
ϕ
Y/
Δ
R
St
[
Ω
]
80SH/4
550-340-A
3.82
50
1415
1.38
400
0.55
0.7
Y
9.34
80LH/4
750-340-A
5.21
50
1410
1.8
400
0.75
0.75
Y
6.30
90SH/4
111-340-A
7.53
50
1430
2.46
400
1.1
0.8
Y
4.96
90LH/4
151-340-A
10.3
50
1420
3.38
400
1.5
0.79
Y
3.27
100LH/4
221-340-A
14.6
50
1445
4.76
400
2.2
0.79
Y
1.73
100AH/4
301-340-A
20.2
50
1420
6.4
400
3.0
0.77
Δ
4.39
112MH/4
401-340-A
26.4
50
1440
8.12
400
4.0
0.83
Δ
2.96
132SH/4
551-340-A
36.5
50
1455
10.82
400
5.5
0.83
Δ
1.84
132MH/4
751-340-A
49.6
50
1455
15.08
400
7.5
0.8
Δ
1.29
160MH/4
112-340-A
72.2
50
1465
20.5
400
11.0
0.85
Δ
0.78
160LH/4
152-340-A
98.1
50
1465
27.5
400
15.0
0.87
Δ
0.53
180MH/4
182-340-A
122
50
1475
34.9
400
18.5
0.84
Δ
0.36
180LH/4
222-340-A
145
50
1475
40.8
400
22.0
0.86
Δ
0.31
* at rated point