3.2
Technology unit overview
BU 0500 GB
Subject to technical alterations
47
Parameterisation with the ControlBox
The frequency inverter can only be controlled via the ControlBox, if it has not previously been enabled via the
control terminals or via a serial interface (P509 = 0 and P510 = 0).
If the "START" key is pressed, the frequency inverter in the operating display changes (selection P001). The
frequency inverter supplies 0Hz or a higher minimum frequency (P104) or jog frequency (P113) which has
been set.
STOP
Store current frequency
as jog frequency
Set frequency= 0Hz (press
simultaneously)
Increase frequency
Change rotation direction
Decrease frequency
START
Parameter set display
Quick stop
(press simultaneously)
Parameter set display:
The LEDs indicate the actual operating parameter set in the operating display (P000) and the current
parameter set being parameterised (
≠
P000). There, the display appears in binary form.
The parameter set can also be changed during operation via the parameter P100 (control via ControlBox).
Frequency setpoint:
The current frequency setpoint depends on the setting in the parameters jog frequency (P113) and minimum
frequency (P104). This value can be altered during keyboard operation with the value keys
and
permanently stored in P113 as the jog frequency by pressing the ENTER key.
Quick stop:
By simultaneously pressing the STOP key
and the "Change direction key”
, an quick stop can be
initiated.