58
LIBERO LINE FRY TOP INDUCTION
A
la
rm
c
ode
Invol
v
e
d
c
om
po
nent
P
owe
r
di
s
a
-
bl
e
S
e
lf
-re
s
e
t-
ti
ng
Alarm name
Alarm description
Alarm trou-
ble shoot-
ing
E431
E432
POW
Yes
Yes
TEMP SENS
SLOPE_Z0 (Front
zone on Tesla
POW)
TEMP SENS
SLOPE_Z1 (Rear
zone on Tesla
POW)
Implemented on Tesla POW only:
Slope detection alarm
(temperature not increasing, stuck,) on front or rear coil. This
diagnostic is only active when zone temperature is below
55°C. Intervention time depends on requested power:
•
Level 8, 9, 10 : 2 min 30 sec
•
Level 7 : 4 min 30 sec
•
Level 5, 6 : 7 min
•
Level 4 : 9 min 30 sec
•
Level 3 : 14 min
•
Level 1,2 : More than 3h
The error is self-resetting after two minutes that the U.I. is
OFF or COOLING_DOWN state.
NOTE:
For Tesla POW with single zone configurations this
diagnostic help to diagnose the reversal of the sensor with the
dummy resistor (100kOhm resistance).
Check temp
sensors,
DUMMY
sensor has
been
swapped
position af-
ter .Part re-
placement.
E441
E442
POW
Yes/
No
Yes
PLATE_TEMP_SE
NSOR_Z0
(Front zone on
Tesla POW)
PLATE_TEMP_SE
NSOR_Z1
(Rear zone on Tesla
POW)
Tesla HC, HOB & WOK:
Wrong electrical connection: A
cooking plate temperature sensor is present on BT300 or
BT400 connector. In this case the error is not self-resetting.
Tesla POW, FRYTOP:
Two possibilities:
Cooking plate temperature sensor open, not connected, bad
circuit or short circuit. Bad circuit means temperature ≥ 290°C
on Tesla POW.
HOB or WOK configuration loaded in a FRYTOP appliance.
The error is self-resetting in case of sensor open or not con-
nected, not self-resetting in case of bad circuit or short circuit.
NOTE:
Diagnostic is executed on both generators (Front and
Rear) within the single Tesla POW § 4.4.7.3.4.
Check temp
sensors,
DUMMY
sensor has
been
swapped
position af-
ter
Spare
Part
re-
placement
E501
U.I
No
No
The alarm is showed on both display (left and right). On Libero
Line this may happen when a wrong firmware is used for the
hardware.
Check cor-
rect
U.I.
spare part
E601
POW
No
Yes
15V BAD
15 Volt supply out of window
Check volt-
age
E611
E612
POW
Tesla
: Yes
Fou-
cault:
No
Yes
Tesla:
IGBT_TEMP_SENS
Fouc:
SENS_ERR_IGBT
Tesla POW:
IGBT/heat-sink sensor open or short or >130°C
(115°C for deactivation). One single error for both IGBT tem-
perature sensors within an POW.
Foucault HC:
IGBT/heat-sink sensor open or short. The error
is self-resetting
Overheat-
ing, Check
cleaning fil-
ters, clean-
ing of venti-
lators fans
(dirt
accu-
mulation on
fan blades)
E641
POW
Yes
Yes
RELAY GLUED
APD relay glued, can’t switch off power induction circuits.
Check POW
E651
POW
Yes
Yes
ADJACENT
ADC
PIN FMEA ERROR
Solder/assembly fault inside power board: short circuit on ad-
jacent pin of safety ADC.
NOTE:
On Tesla POW, this error appears (on both genera-
tors) if a coil temperature sensor is disconnected / recon-
nected when the POW board is already powered on.
Check temp
sensors
connectors
E661
POW
Yes
No
DATA_CRC_ER-
ROR
Foucault POW only:
Internal power table missing.
Foucault POW software is equipped with an internal power
table to be used when the POW is connected without an UI
and power level set is established by a potentiometer (modu-
lar cooking range).
Even if not used on Libero Line, the POW software check the
presence of the internal power table at power-on
Wrong
spare part.
E6A1
POW
Yes
Yes
MAINS
FRE-
QUENCY ERROR
Power supply frequency detection error.
Acceptable range: 40% to 60% of the duty cycle @50Hz.
Check
Power sup-
ply
fre-
quency
Summary of Contents for 406600899
Page 1: ...Service Manual Fry Induction Top IGEC 3P 2ZQT Art 406600899 2021 04 ...
Page 13: ...13 LIBERO LINE FRY TOP INDUCTION DOUBLE ZONE ...
Page 21: ...21 LIBERO LINE FRY TOP INDUCTION In case of need the supply cable can be replaced removed ...
Page 44: ...44 LIBERO LINE FRY TOP INDUCTION ...
Page 45: ...45 LIBERO LINE FRY TOP INDUCTION ...
Page 47: ...47 LIBERO LINE FRY TOP INDUCTION ...
Page 48: ...48 LIBERO LINE FRY TOP INDUCTION ...
Page 50: ...50 LIBERO LINE FRY TOP INDUCTION ...
Page 51: ...51 LIBERO LINE FRY TOP INDUCTION ...
Page 54: ...54 LIBERO LINE FRY TOP INDUCTION ...