Avoid using aggressive detergents and dry with a damp cloth (a dry cloth would create
electrostatic charges).
ATTENTION : DO NOT WASH THE CABINET WITH WATER JETS.
At least every two months clean the condensor from dust, webs, etc.
Take off the front grill and clean with a brush or a vacuum cleaner
(fig.7)
.
This operation is extremely important to assure a good and long performance
of the cabinet.
If the cabinet is supplied with the condenser self cleaning system this operation
is not necessary.
REPLACEMENT OF THE LIGHTING LAMP
To replace a lamp in case of bad functioning, follow carefully the instructions:
1. Unplug the cabinet
2. Take off the plastic protection of the lamp
3. Turn the fluorescent tube and remove it from its holder
4. Fix the new fluorescent tube and make sure that it is the same of the previous one.
5. Reassemble the lamp protection
6) Plug the cabinet in.
7 >
TROUBLE SHOOTING
A
>
the cabinet does not start
check the connection between plug and socket
make sure that the general switch is on
make sure that there is not a black-out in the area
B
>
the cabinet does not refrigerate enough
check for a proper cleaning of the condensor
check that shelves and goods are properly fixed and loaded
check that the cabnet is not placed near heating sources or air current
check that the aspiration grill is not blocked up
!