13
1. INSTALLATION REGULATIONS
Installation of the Product and auxiliary equipment in relation to the heating system must comply with all current Standards and Regulations
and to those envisioned by the law.
The installation and the relating to the connections of the system, the commissioning and the check of the correct functioning must
be carried out in compliance with the regulations in force by authorised professional personnel with the requisites required by the law,
being national, regional, provincial or town council present in the country within which the appliance is installed, besides these present
instructions.
Installation must be carried out by authorised personnel who must provide the buyer with a system declaration of conformity and will
assume full responsibility for final installation and as a consequence the correct functioning of the installed product.
The control unit and the plant must be installed and connected by authorized personnel according to the standards in force
.
ATTENTION: the feeding cable must not be in contact with hot parts
.
CONNECTION
: power supply 230V~ 50/60Hz, it is necessary to provide for the correct connection to the grounding plant.
WARNING:
The Product must be connected to the mains with a differential line cut-off switch according to the regulations in force. Correct
operation of the command is assured only for the proper motor for which it has been manufactured. Improper use relieves the manufacturer
from each responsibility.
LA NORDICA S.p.A. declines all responsibility for damage to things and/or persons caused by the system. In addition, it is not
responsible for any product modified without authorisation and even less for the use of non original spare parts.
2. DISPLAY TECHNICAL FEATURES
2.1. ENVIRONMENTAL SPECIFICATIONS
Ambient operating temperature
From 0°C to 60°C
Storage temperature
From -10°C to +60°C
Maximum relative humidity (without condensate)
95%
2.2. ELECTRICAL SPECIFICATIONS
Power supply
:
Power supply voltage
230Vac 50/60 Hz
Maximum consumption
Maximum power absorption
Fuse protection
2.5 A – 250 Volt
COMB input (normally open)
I1
Contact
Input not used
I2
---------
Load motor reducer cam input (norm. closed)
I3
Contact
Ascent limit switch input (normally closed)
I4
Contact
Descent limit switch input (normally closed)
I5
Contact
Input not used
I6
---------
Outputs
:
Salt trolley motor output (M1_S ascent)
TROLLEY UP
230Vac (RELAY)
Down trolley motor output (M1_D descent)
TROLLEY DOWN
230Vac (RELAY)
Tray motor output (M2)
TRO
230Vac (RELAY)
Fan output
FAN
TRIAC
AUX auxiliary output
AUX
Clean contact (RELAY)
NEUTRAL
NEUTRI
2.3. MECHANICAL SPECIFICATIONS
Board dimensions (L x H)
109,2 – 91,4 mm
Weight
Assembly position
Stove lower compartment
Manual rearm OVERTEMPERATURE safety thermostat
Picture 2 at page 33 Pos. A
Capillary. Max T.85°C