ThIs Image shoWs all PossIble assembly PosITIons WITh relaTIve heIghT IndIcaTIons.
In this regard, please note that installation at a 90° angle generates more heat than discharge flow.
smoke reTurn should be verTIcal or aT an angle of 45°.
Direction of smoKe fan
The forced draught smoke fan, complete with smoke fitting, is supplied disassembled from the boiler.
during installation, the fan is secured to the discharge flange of the boiler together with the fastening nuts and perimeter gasket.
To facilitate installation, the smoke inlet can be installed in different positions, with the option to rotate it by 180°.
attentIon
– the smoke fan Is supplIed dIsassembled. Insert it into the smoke duct at the back, tighten the
wing nuts completely, connect it to the power supply outlet and check if it operates correctly -
suction
.
manDatory
condensation-proof “T” fitting with inspection plug
installing the gasket for the smoke exhaust system
Place the gasket on the flange of the boiler. use a screw (m8x20) to secure it.
secure the smoke exhaust system
in the desired position using 4 m8x20 screws.
20
20