35°C
C
100 %
221°
1 cm
ENGLISH
5. “half-close” the ignition door
after lighting the cardboard or paper, leave the ignition door ajar with a gap of about 1 cm.
if the Door is fully closeD, the flame will Go out.
if the Door remains fully open, smoKe can escape into the boiler room!
6. close the ignition door and the boiler panelling door.
If the smoke temperature is higher than 220°c, the ignition door and the panelling door can be closed.
for example:
Temp.
WaTer
Temp.
smoke
aIr
7. observe the smoke temperature
after closing the doors, the smoke temperature must continue to increase within a few minutes.
The boiler then automatically switches to work mode.
otherwise, it is necessary to open the ignition door again briefly!
When The smoke TemPeraTure has reached 220°c
the Door must be closeD
.
If within 30 minutes after starting the ignition process the smoke temperature does not exceed 100°c, the process is stopped and
the error message, “no IgnITIon”, is displayed.
rePeaT The sTePs descrIbed In The chaPTer “heaTIng (normal oPeraTIon)”.
33
33