16
1. TECHNICAL DATA
Definition in accordance with
EN 13240
Constructive system
Global
thermal power in kW
Nominal
thermal power in kW
Power given back
to water
in kW
Power given back
to the room
in kW
Hourly wood consumption
in kg / h (wood with 20% humidity)
Efficiency
in %
CO
measured at 13% oxygen in %
Smoke outlet
diameter in mm
Chimney
height - dimension in mm (
#
)
Fluid contents of the exchanger
in L (litres)
Chimney draught
in
Pa
(mm H
2
O)
Boiler connections
(Ø)
Automatic discharge pipe
diameter (Ø)
Outer air inlet
Ø in mm
Exhaust gas emission
in g/s – wood
Exhaust gas temperature
in °C - wood
Optimal working temperature
in °C
Max. working pressure
in bar
Hearth opening size
in mm (W x H)
Hearth size
in mm (W x H x D)
Oven
size
in mm (W x H x D)
Type of grill
Movable - flat
Height
in mm
Width
in mm
Depth
in mm
Weight
in Kg
Fire prevention safety distances
Chapter FIRE SAFETY
heatable m
3
(30 kcal/h x m
3
) (
# #
)
(
#
) 200 mm diameter can be used with flue of no less than 6 m.
(
# #
)
For those buildings in which the thermal insulation does not correspond to the instructions on heat protection, the heating volume
of the product is: favourable type of building (30 Kcal/h x m
3
); less favourable type of building (40 Kcal/h x m
3
); unfavourable type of
building (50 Kcal/h x m
3
).
With thermal insulation in accordance with the regulations regarding energy saving, the heated volume is greater. With temporary heating,
in the event of interruptions which last more than 8 hours, the heating capacity is reduced by about 25%.
IMPORTANT
: The power of the connected heating system must be proportional to the power transferred to the water by the thermoproduct;
a charge which is too low does not allow regular oven operation, while a charge which is too high prevents adequate radiator heating.
2. GENERAL PRECAUTIONS
La NORDICA S.p.A. responsibility is limited to the supply of the appliance.
The installation must be carried out scrupulously according to the instructions provided in this manual and the rules of the profession.
Installation must only be carried out by a qualified technician who works on behalf of companies suitable to assume the entire responsibility
of the system as a whole.
La NORDICA S.p.A. declines any responsibility for the product that has been modified without written authorisation as well as for
the use of non-original spare parts. NO MODIFICATIONS CAN BE CARRIED OUT TO THE APPLIANCE. NORDICA S.p.A. cannot
be held responsible for lack of respect for such precautions.
It is OBLIGATORY to respect the National and European rules, local regulations concerning building matter and also fireproof
rules.
3. INSTALLATION REGULATIONS
Installation of the product and auxiliary equipment in relation to the heating system must comply with all current Standards and Regulations
and to those envisioned by the law.
The installation and the relating to the connections of the system, the commissioning and the check of the correct functioning must
be carried out in compliance with the regulations in force by authorised professional personnel with the requisites required by the law,
being national, regional, provincial or town council present in the country within which the appliance is installed, besides these present
TermoISOTTA - DSA
1
19.1
15
8,5
6,5
4.4
78.4
0.10
150
4m 250x250 Ø250 / 5m – 220x220 Ø220
14,5
17-20 (1,7 - 2,0)
1 ”F gas
½”M gas
200 (314 cm
2
)
14.7
278
70-75
VA 1,5 bar - VEC 3 bar
519 x 340
570 x 300 x 325
/
775
760
520
212
430