Installation of indoor unit
at least 3cm
above the floor
Installation of outdoor unit
(select it according to the actual installation situation)
1. Select installation location according to the house structure.
2. Fix the support of outdoor unit on the selected location with expansion screws.
23
Note:
● Do not bend the drain hose too excessively in order to prevent blocking.
indoor
outdoor
wall pipe
sealing gum
upper hook
lower hook of
wall-mounting frame
Note:
2. Connect the drain hose into the drain vent.
chassis
outdoor drain joint
drain vent
Drain hose
Connect the outdoor drain joint into the hole on the chassis, as shown in the
picture below.
Step two: install drain joint (Only for some models)
1.
NOTE:
As for the shape of drainage
joint, please refer to the current
product. Do not install the drainage
joint in the severe cold area.
Otherwise, it will be frosted and
then cause malfunction.
Take sufficient protective measures when installing
the outdoor unit.
Make sure the support can withstand at least four
times of the unit weight.
The outdoor unit should be installed at least 3cm
above the floor in order to install drain joint.(for the
model with heating tube, the installation height should
be no less than 20cm.)
For the unit with cooling capacity of 2300W~5000W, 6
expansion screws are needed;for the unit with cooling
capacity of 6000W~8000W, 8 expansion screws are
needed; for the unit with cooling capacity of
10000W~16000W, 10 expansion screws are needed.