Determination of steam absorption distance

Determination of the absorption distance “B

N

” depends on various factors. 

For simple determination of the absorption distance “B

N

” the table can be 

used. The nominal values obtained from the table re fer to an air inlet tem-

perature of 10 °C to 30 °C. The result must be compared with the actual 

steam absorption distance or with the minimum spacings to be observed.  

1.4 

Notes on installation

Before installation check that the correct MultiPipe system is used and 

that the system is in accord ance with the type and steam out put on the 

specification label. 

The MultiPipe is suitable for instal lation in air ducts or air-conditioning units. 

For this purpose the tem plates supplied are attached to the ventilation duct 

spaced according to the collectors. The duct plate is cut out round. The con-

nection side of the pre-fitted system is inserted from inside through these 

holes. The connector pieces are then fit ted on the pipes from outside and 

screwed to the duct wall. The col lector pipes should be aligned hor izontally 

and secured at the end on the duct wall. 

For large systems or in special cas es, where this type of installation is not 

possible, the collector pipes can be fitted individually from out side. The noz-

zle tubes are then in serted in the collectors in the air duct and secured with 

the pipe clamps and O-rings. Suitable pliers are required for the installation. 

All parts are supplied loose for this case if required. 

Then install the steam and condensate hoses according to the instructions 

in the installation and operating instructions of the humidifier. It is advisable 

to drain the con densate separately and not return it to the humidifier owing 

to the in creased volume. 

Summary of Contents for MultiPipe

Page 1: ...INSTALLATION AND OPERATING INSTRUCTIONS NORDMANN E N G I N E E R I N G MultiPipe 2557005 EN 1406 Steam distribution system ...

Page 2: ......

Page 3: ...mension diagrams 6 2 3 Power selection diagram MultiPipe Systems 1 4 7 2 4 Type key 7 2 5 Determination of the humidification distance BN 8 2 6 Planning data MultiPipe steam distribution system for faxing 8 3 Mounting 9 3 1 Safety 9 3 2 Delivery 9 3 3 Mounting positions 9 3 4 Mounting the premounted MultiPipe system 10 3 5 Mounting the different parts of the MultiPipe system 11 3 6 MultiPipe Suppo...

Page 4: ... should be deter mined when laying out the air con ditioning system The following points should be ob served to en sure correct humidification of the air The conditions must be main tained exactly to ensure that the MultiPipe system satisfies the high demands made of it A layout based on incorrect data an unfavourable installation position or wrong instal lation can result in excessive hu midity w...

Page 5: ...d according to the collectors The duct plate is cut out round The con nection side of the pre fitted system is inserted from inside through these holes The connector pieces are then fit ted on the pipes from outside and screwed to the duct wall The col lector pipes should be aligned hor izontally and secured at the end on the duct wall For large systems or in special cas es where this type of inst...

Page 6: ...nections of the steam humidifier This also determines the maximum steam output The max imum possible collector lengths and collector spacing is selected depending on the duct width and height 2 2 Dimension diagrams 90 A L D1 Ø 30 Ø 60 3 D2 H H Ø 35 0 D1 D1 D1 D1 60 B 90 A L D1 Ø 30 Ø 60 3 D2 D2 120 H Ø 35 0 D1 D1 D1 D1 60 B MultiPipe System 1 2 System 4 MultiPipe System 4 Systems 1 and 2 ...

Page 7: ...50 1650 System 2 mD max kg h 45 65 D2 mm 350 500 650 800 1000 1200 1500 1800 2000 H min mm 450 600 800 950 1150 1350 1650 1950 2200 System 4 mD max kg h 90 130 D2 mm 300 375 475 575 725 875 1050 1200 1350 1500 H min mm 800 950 1150 1350 1650 1950 2300 2600 2900 3200 Systems 1 and 2 for single units only System 4 for double units only 2 4 Type key X XXX XXX XXX No MultiPipe system Collector length ...

Page 8: ...m for faxing Layout data required Installation 1 Installation 2 Installation 3 Installation 4 1 Clear height of air duct B without insulation mm 2 Clear width of air duct H without insulation mm 3 Wall thickness of air duct A without insulation mm 4 Air volume per hour or m3 h 5 Air speed m s 6 Air duct static pressure Pa 7 Temperature after humidification C 8 Abs humidity before humidification g ...

Page 9: ...l ducts When mounting in a vertical duct the nozzle pipes must have a minimum declination of 20 and the end pieces of the collector pipes must be turned so that the vertical condensate connection directs straight downwards see figure below Note Before mounting the MultiPipe system check the type designation and steam capacity on the data plate to ensure that the correct MultiPipe system is install...

Page 10: ...eam hose connection 5 Starting with the lowest collector pipe fix the steam hose connections with the 4 screws at the duct wall 6 Align the collector pipes with a down slope of 2 against the steam con nector Then fasten the pipe ends on the duct using M8 threaded rod or the specially designed support available as accessory see mounting drawing in chapter 3 6 7 Connect the steam hose and the conden...

Page 11: ...tuated one against the others With a suitable clamp press both halves of the clips together until they will be fixed by a click 5 Starting with the lowest collector pipe fix the steam hose connections with the 4 screws at the duct wall 6 Align the collector pipes with a down slope of 2 against the steam con nector Then fasten the pipe ends on the duct using M8 threaded rod or the specially designe...

Page 12: ...y Range duct height mm Art No Foothold Pos 1 No x Length mm Rail Pos 2 mm Bracket Pos 3 450 950 1117477 1 x 450 mm 500 4 950 1350 1117478 2 x 450 mm 500 4 1350 2300 1117479 2 x 450 mm 1400 4 2300 3200 1117480 2 x 450 mm 2300 4 1 1 2 3 ...

Page 13: ...pical 500 Pa and the back pressure in the steam hose typical 100 Pa m 2 that no water splashes from the steam distribution system and the con densate runs out of the system satisfactorily Condensating forma tion may be caused by Steam supply pipe not properly drained Metallic steam pipe inadequately insulated Overstressed steam generator feeds water through steam pipe System condensate drain is bl...

Page 14: ... x ø5 34 3 pcs 2556745 3 Sealing cap with fixation 2556746 4 Sealing cap ø10 3 pcs 2559240 5 Hose clamp DS35 2 pcs 2539583 6 Internal sealing 2556747 7 Pipe clamp with O ring 2556748 8 O ring for pipe clamp 5 pcs 2556749 Sealing cap ø41 2567040 5 Spare parts list 1 4 5 2 6 3 7 8 ...

Page 15: ... Nordmann Engineering Ltd Printed in Switzerland Technical modifications reserved ...

Page 16: ...NORDMANN E N G I N E E R I N G NORDMAN E N G I N E E R I Dampfluftbefeuchter econ Reg No 40002 2 Manufacturer Nordmann Engineering Ltd www nordmann engineering com info nordmann engineering com ...

Reviews: