10
GB
1. General information
Weight
The home owner must ensure that the floor can
withstand the load according to the total weight of the
fireplace. When installing the product on a floating wood
floor, the floor boards underneath the fireplace must be
removed, this to avoid the that the floor boards lock and
crack.
Chimney connection
Follow the chimney manufacturer’s specifications for
connection to the chimney. We recommend to dry stack
the surround without glue in order to adjust the insert
prior to perforating the chimney for the flue connection.
Remember that the insert will expand with heat, so the
surround cannot rest on the insert, but have a distance
of about 2-3mm. The insert must neither rest against the
bench plate or against the sides.
For top connection to steel chimney please follow the
assembly instructions of the producer.
Acrylic glue
Glue the elements with the acrylic which is included.
Ensure that all surfaces that are to be glued are dust
free. Once the fireplace is assembled, fill the joints
between the elements with acrylic and even the groove
with a sponge or finger and some soapy water, in order
to have a clear indentation between the elements (FIG
Z).
Powder glue for filling
The powder glue which is included can be used to repair
damages in the concrete. Mix the provided powder glue
with water (the consistency of the glue should be that of
tooth paste). Dampen the surface with a damp sponge.
This will remove dust and ensure better adhesion.
Minor dents
Transportation and handling can cause minor dents to
the product. This can be repaired with the powder glue
which is included. For a perfect result you can putty with
a suitable filler on top of the powder glue.
Putty smaller cracks and uneven surfaces. It is
recommended to fill in several stages to avoid sinking if
the dent is deep. Even out with e.g. a damp sponge or
a float.
Smaller damages
New houses shift and settle during their first years and
in addition the concrete elements shrink in lessening
degree during the first 15 months. As a result cracks
may appear in the joints between the elements of the
surround, on the firewall and chimney.
Do as follows: Use the fireplace for a few months.
If there is a crack, tear it up a little with a e.g. a
screwdriver (to provide more space for the filler)
and then vacuum clean to remove all the dust. Inject
acrylic filler and smoothen with a wet soapy sponge or
fingertip. After a few days the groove can be repainted.
1. Prior to assembling the insert
10
Weight
10
Chimney conntection
10
Acrylic glue
10
Powder glue for filling 10
Minor dents 10
Smaller damages 10
Painting 11
Marble/granite 11
2. Before installing a new fireplace
11
3. Technical information 11
4. Distance to combustible material
12
5. Assembly
12
Assembly instructions for the insert
12
Flue outlet
12
Connection of the flue
12
Operating control
13
Thermotte™ plates
13
Assembly instructions for the surround
13
6. Lighting the fire for the first time
13
7. Maintenance
14
Cleaning and inspection
14
Ashes 14
Thermotte™ plates
14
Door and glass
14
Recycling of the refractory glass
14
8. Warranty
15
9. Advice on lighting a fire
15
Some advice in case of combustion problems
16
INDEX
ATTENTION!
This manual is for NO/DK/SE/FI only.
For assembling this product in the UK,
please see separate manual.
Summary of Contents for CC-RIO00-100 Ronda
Page 38: ...38 2000 600 641 1240 336 Ronda mm Ronda air 625 135 140 ...
Page 41: ...41 X FIG 3 FIG 4 ...
Page 42: ...42 FIG 5A FIG 6 FIG 7 FIG 5B FIG 8 FIG 9A FIG 9B ...
Page 43: ...43 FIG 10 FIG 11A FIG 11B FIG 12 G H F I ...
Page 45: ...45 FIG 14 FIG 15 FIG 13 124 mm 2 1 3 FIG 16 2 165 FIG 15b ...
Page 46: ...46 FIG 18 FIG 19 FIG 20 5 6 2 mm 641 mm 4 4 FIG 17 ...