Safety
1-9
E
1995 Nordson Corporation
All rights reserved
Issued 11/95
12–28s1
S
Check interlock systems periodically to ensure their effectiveness.
S
Check all ground connections periodically with a megohm meter.
Resistance to ground must not exceed one megohm. If sparks or
arcing occur, shut down the system immediately.
S
Disconnect, lock out, and tag electrical power at a disconnect or
breaker in the service line ahead of electrical equipment before
servicing.
WARNING: Service lines connected to panel disconnect
switches may still be energized unless they are disconnected.
Make sure the power is off before servicing. Wait several
minutes for capacitors to discharge after shutting off the
electrical power.
S
If a “power on” test is required, perform the test carefully and then
shut off and lock out power as soon as the test is over.
S
Do not attempt to service electrical equipment if there is standing
water present. Do not service electrical equipment in a high-humidity
environment.
S
Use tools with insulated handles when working with electrical
equipment.
S
Keep high-voltage connection points clean and insulated with
dielectric grease or oil.
S
Do not attempt to service a moving piece of equipment. Shut off the
equipment and lock out power. Secure equipment to prevent
uncontrolled movement.
WARNING: Hot! Risk of burns. Wear heat-protective clothing,
eye protection with side shields and/or heat-protective gloves.
Heated materials may cause severe burns on contact. Remember that
some materials, even solid materials, may retain heat for some time. If
you are burned by a heated material, immediately cool the affected skin
with lots of cool, clean water. Do not try to remove hot, melted material
from the skin. Seek immediate medical attention.
9. Maintenance and Repair
(contd.)
10. Material and Solvent
Precautions
Summary of Contents for 107 041A
Page 1: ...Select Cure 100 Inch IR Oven Part 107 041A NORDSON CORPORATION D AMHERST OHIO D USA ...
Page 9: ...E 1995 Nordson Corporation All rights reserved Issued 11 95 12 28s1 Section 1 Safety ...
Page 10: ...Safety 1 0 E 1995 Nordson Corporation All rights reserved Issued 11 95 12 28s1 ...