Follow these guidelines when installing wiring to the unit:
S
Allow enough room to route your electrical service line to the unit.
You can use either of the two access holes in the base of the unit for
electrical service. One hole is for rear access and the other is for
bottom access.
S
Route any wires away from AC power lines, solenoid output lines,
and electrical equipment such as motors, contacts, and relays.
S
Make connections with the minimum length of wire needed. A long
wire can act as an antenna for electrical noise.
The power requirements of your hoses and guns must be determined to
make sure that you do not overload the unit. If your Nordson
representative has not already checked to see that your unit can support
all of the hoses and guns you plan to install, you need to calculate your
hose/gun power requirements now. You also need to check your
calculations if you change your system configuration or add new hoses
and guns.
To determine your hose/gun power requirements, refer to
Calculating
Hose/Gun Capacity
at the end of this manual. If you need help with this
procedure, contact your Nordson representative.
Wiring Requirements
Hose/Gun Power Requirements