background image

Instruction Sheet

E

2000 Nordson Corporation

All rights reserved

321 355A

Issued 5/00

41--3000--IS--65

P/N 321 355A

Setup Instructions for Series 3100V Level Switch

WARNING:

Allow only qualified personnel to perform the

following tasks. Observe and follow the safety instructions in

this document and all other related documentation.

When the adhesive level in the Series 3100V melter is low, the low-level

switch magnetically closes a dry reed switch which is connected to an

external device. The external device can automatically add more

adhesive or illuminate a light that warns operators when the adhesive

level is low.

The low-level switch consists of a float switch, shield, and terminal block.

The float rides half in and half out of the adhesive. As the adhesive level

drops, the float drops, signaling the terminal block.

The switch is intended for 30 VAC maximum, 30 W, less than 0.28 A,

Class 2 circuit operation as defined in Article 725 of the National

Electrical Code.

WARNING:

Hot! Risk of burns. Wear heat-protective clothing,

safety goggles, and heat-protective gloves. Hot melt material

may be release forcefully.

Follow this procedure to assemble the low-level switch

1. Introduction

2. Installation

Assembling the Low-Level

Switch