1500XL
❶
Connect the air input hose to a plant air source. Set plant air
supply within 80 to 100 psi (5.5 to 6.9 bar). Where required, use
an EFD five-micron filter regulator #2000F755 (see Warranty).
❷
Attach the air input hose coupling to the dispenser. Pull back
metal ring to attach to dispenser.
❸
Plug in the polarized foot pedal connector.
❹
Check the voltage label on the input voltage selector cartridge.
To change the voltage, remove the voltage selector from the
cartridge, rotate it and position the correct voltage to show
through the cartridge window. Replace the cartridge into the
power cord receptacle and insure that both sides snap securely
into position. Install the power cord.
Note:
For 1500XL-15 and 1500XL-CA dispensers, use the test barrel
filled with clear fluid and the red 25 gage tip. Refer to "
Making Timed
Deposits of Watery-thin Fluids
" on page 22.
❺
Attach the 10cc barrel prefilled with blue, nontoxic test fluid
(included with the dispenser) to the 10cc adapter head.
❻
Take the 10cc adapter assembly (#5150 on the adapter head)
and insert the black, male quick-connect into the air output fitting
on the front panel and turn clockwise to lock. Place the barrel in
the barrel stand.
❼
During the initial testing, you will not use the vacuum control.
Keep this control shut off (turned completely clockwise—do not
force).
1500XL -- Hookup
9
Spare Fuse
Cartridge Window
(check voltage indicated)
Note: The dispenser is
shipped with the fuse
cartridge set for 120
VAC input.
Voltage Value
Pin Function
1.
In
2.
Initiate
3.
4.
Output
5.
Contact Closure
6.
Chassis Ground
7.
Contact Closure
8.
Not Used
9.
Not Used
]
]
I/O Connection
The 9 pin D connector and
internal circuitry provides
external initiate with end-of-
cycle feedback. The pin
connections are shown
below. For complete sche-
matic and detailed infor-
mation, please contact EFD.
5-24 VDC
250 mA Max
5-24 VDC
6
7
8
9
1
2
3
4
5
220
120
100
Note:
A 9-pin male connector
assembly is available from
EFD (order part #7154).