© 2022 Nordson Corporation
4-4
Converting from Flat Spray Nozzles to Optional Conical Nozzles
WARNING:
Turn off the interface, and ground the electrode before performing this
procedure. Failure to observe this warning could result in a severe electrical shock.
NOTE:
To clean nozzles, use the
Recommended Cleaning Procedure for Powder
Contact Parts
NOTE:
The tapered flat spray electrode holder shipped with the spray gun will need to
be changed in order to accept the conical nozzles and deflectors. The optional conical
nozzle kit is required for this conversion.
1.
Purge the spray gun and turn off the interface in order to prevent accidentally
triggering the spray gun on.
2. Convert the electrode holder and the nozzle. See Figure 4-2.
a.
Unscrew the nozzle nut counterclockwise and remove it. Pull the flat spray nozzle
off the electrode assembly.
b.
Remove the tapered flat spray electrode holder. Do not bend the electrode wire.
c. Install the non-tapered conical spray electrode holder over the electrode.
d. Install the conical spray nozzle on the electrode assembly. The nozzle is keyed to
the electrode assembly. Screw the nozzle nut onto the spray gun body clockwise
until finger-tight. Install a deflector on the electrode assembly. Do not bend the
electrode wire.
Conical Spray Nozzle
Deflector
A
D
C
B
Figure 4-2 Converting from a Flat Spray Nozzle to a Conical Spray Nozzle
Summary of Contents for Encore Select HD
Page 6: ...2022 Nordson Corporation 1620445 03 ii Change Record...
Page 10: ...2022 Nordson Corporation 1620445 03 1 4 Safety...
Page 14: ...2022 Nordson Corporation 1620445 03 2 4 Overview...
Page 20: ...2022 Nordson Corporation 1620445 03 3 6 Setup...
Page 34: ...2022 Nordson Corporation 1620445 03 5 6 Repair...