FoamMix Flex Foaming System
18
Part 1129048_01
E
2020
Nordson Corporation
Installation
This section provides procedures for connecting power the equipment that
form the advanced foaming system.
WARNING!
Allow only qualified personnel to perform the following tasks.
Follow the safety instructions in this document and all other related
documentation.
WARNING!
Risk of electrocution! Disconnect power to the advanced
foaming station at the customer-installed power disconnect switch. Failure to
install or properly use the disconnect switch when working inside the
advanced foaming unit electrical compartment can result in personal injury,
including death.
Mount the Equipment
For details on how to mount the equipment, refer to the following product
manuals:
S
AltaPail II bulk melter
S
Pro‐Meter VDK dispensing module
S
Pro‐Meter VDK controller
S
FoamMix Flex foaming station
Connect
the FoamMix Flex Foaming System
This section describes how to connect the equipment. For cable part
numbers, refer to
Parts Lists
given at the end of this manual.
Connecting the
High Pressure
Hoses
Refer to the instructions provided with the automatic hose for detailed
installation information.
1. Connect a 3/4‐inch HP hose from the outlet of the bulk melter and the
silicone inlet port of the advanced foaming unit.
2. Connect a 3/4‐inch HP hose from the advanced foaming unit outlet to
inlet of the ProMeter VDK dispensing module.
NOTE:
If using two Bulk Unloaders, use a change‐over manifold to
connect to the advanced foaming station.