FoamMix Flex Foaming System
19
Part 1129048_01
E
2020
Nordson Corporation
Connecting the Nitrogen Supply
WARNING!
Risk of Explosion. Compressed gas cylinders can explode or act
as projectiles if punctured or the valve assembly is damaged. Ensure that the
nitrogen cylinder is restrained in an upright position and placed where it
cannot be damaged by moving equipment.
1. Restrain the nitrogen cylinder.
2. Install the Nordson or customer supplied nitrogen pressure regulator on
the nitrogen cylinder. Ensure that the regulator control knob is turned fully
counterclockwise (no pressure).
NOTE:
The Nordson‐supplied nitrogen pressure regulator has two
adjustment knobs, the stainless steel knob is factory set and locked.
DO NOT
adjust this knob or foam quality will be adversely affected.
NOTE:
If the Nordson pressure regulator is used with your system it may
be either a 6000 psi high-pressure regulator (P/N 1082050) or a 3000 psi
low-pressure regulator (P/N 1082051).
3. Remove the shipping plug from the gas supply connection and then
install the gas line adapter fitting (P/N 713411) provided in the installation
kit. PTFE tape is provided for this installation.
4. Connect the reinforced PTFE gas line (P/N 332930) between the
regulator output and the gas supply connection on the advanced foaming
unit. A PTFE tape is provided in the installation kit.
5. Open the gas regulator and check for gas leaks at both ends of the gas
line. Leak testing solution is provided in the installation kit.