FoamMix Flex Foaming System
22
Part 1129048_01
E
2020
Nordson Corporation
Connecting the FoamMix Flex Foaming Station to the
ProMeter VDK Controller
A
B
3
4
1
2
3
5
6
7
8
9
10
4
Figure
7
FoamMix Flex foaming station to VDK controller connections
Cable
Connector Details
Purpose
A
Cable is connected internally from the VDK dispensing module to
the VDK controller servo drive.
Motor power
B
Encoder
3
Cable is connected from the VDK dispensing module to the
Pressure Transducer 1
on the VDK controller.
Pressure Transducer 1
4
Cable is connected from the VDK dispensing module to the
Applicator Control 1
on the VDK controller.
Solenoid