FoamMix Flex Foaming System
26
Part 1129048_01
E
2020
Nordson Corporation
To Connect the Signal Cable
See Figures 9 and 10 on page 27.
1. Disconnect power to the FoamMix Flex foaming station at the
customer‐installed power disconnect switch.
2. At the bulk melter, install the strain relief provided in the installation kit
into an available electrical penetration. Refer to the Bulk Unloader
manual for the location of the electrical penetrations.
3. Route the signal cable provided in the installation kit through the strain
relief and into the melter's electrical compartment.
4. Connect the two signal wires to the any pair of available output terminals,
and then tighten the strain relief. Refer to the Bulk Unloader manual for
the location of the output terminal block.
5. When supplying two or more FoamMix Flex foaming stations from a
single melter, each unit must be connected to a discreet bulk melter
output.
6. Route the signal cable over to the FoamMix Flex foaming station.
7. Run the end of the signal cable through the strain relief provided in the
installation kit (P/N 306366), and then into the signal cable penetration on
Side 3 of the FoamMix Flex foaming station.
8. Remove the panel from Side 1.
9. Route the signal cable through the inside of the FoamMix Flex foaming
station, and then connect the two signal wires to terminals 1 and 2 for
120V units or terminal 1 and terminals 4, 5, or 6.
10. Thread the strain relief onto the side of the FoamMix Flex foaming station
and tighten it securely.
To Set Up the Output Signal at the Bulk Melter
1. Refer to the Bulk Unloader manual for detailed information about how to
set up bulk melter outputs. Standard bulk melter outputs 1, 2, and 3 are
controlled respectively by parameters 40, 41, and 42.
2. Set the control option for the appropriate output parameter to option 2,
Ready and the motor is on
.