background image

4

Maintenance 

The following procedures describe the maintenance

required to keep the system operating at its

maximum efficiency.

Daily 

1. Shut off electrostatic voltage to the system.

2. Shut off compressed air to the system.

3. Shut off the fluid supply to the system.

4. Squeeze the trigger on the spray device to relieve

compressed air pressure.

5. Open the cabinet door.  Move the shuttle to

manually separate the couplings.

6. Clean the male and female couplings with a

compatible cleaning solution to prevent coating

material buildup.

7. Apply a small amount of compatible lubricant to

both couplings.  This will keep the coating

material from sticking and will facilitate cleanup.

8. Close the cabinet door.

Weekly 

1. Shut off electrostatic voltage to the system.

2. Shut off compressed air to the system.

3. Shut off the fluid supply to the system.

4. Squeeze the trigger on the spray device to relieve

compressed air pressure.

5. Flush the system with a compatible cleaning

solution, as needed, following steps 1

5 in

Changing Coating Material or Cleaning the

System.

6. Open the cabinet door.  Move the shuttle to

manually separate the couplings.

7. Clean the male and female couplings with a

compatible cleaning solution.  Lightly coat the

female coupling shafts with O-ring grease.  Use a

stiff brush to work the grease through the spring.

8. The lubrication cup is located on the front of the

pump.  Unscrew the plug on the top of the

lubrication cup and add 

1

/

2

 ounce of properly

diluted Q-solvent to the cup.

NOTE:  

Fill the lubrication cup to the bottom of its

vent hole.  This will equal the 

1

/

2

 ounce of properly

diluted Q-solvent that is needed.
9. If your Iso-Flo unit is not equipped with an air

lubricator, remove the air supply hose and add

5

10 drops of lightweight valve oil into the

1

/

4

-in. NPT fitting labeled COMPRESSED AIR on

the side of the unit.

10. Close the cabinet door.

Issued 04/15

Original copyright date 1997.  Iso-Flo, Nordson, and the Nordson logo are registered trademarks of Nordson Corporation.

Reviews: