4110132
Heated Hoses PG...
5
E
1998 Nordson Corporation
All rights reserved
45--PG--MA--01 (formerly PG...)
Issued 10/98
P/N 317163B
Installation
WARNING:
Allow only qualified personnel to perform the
following tasks. Observe and follow the safety instructions in
this document and all other related documentation.
CAUTION:
Unroll the hose when unpacking to avoid bending
or pinching.
In order to guarantee long operating life and safe operation, observe the
installation instructions when laying heated hoses (see Fig. 3).
Ensure proper ventilation of covered hoses to avoid overheating.
Observe minimum bending radius of 150 mm.
WARNING:
Disconnect equipment from the line voltage before
plugging or unplugging electrical hose connections. Observe
national installation practice and corresponding safety
regulations.
1. Switch off the unit’s main switch.
2. Disconnect power cable and secure against re-connection.
1. Disconnect and lock out power to the main circuit breaker for the
applicator input power line.
2. Move the applicator circuit breaker to the OFF position.
Fig. 2 Disconnecting and Locking
Out Main Power
1. Unpacking
2. Installing
Minimum bending radius
3. Electrical Connection
Units with Plugs
Units with Fixed Connection