-5-
-4-
6. U ser s e tt in gs
4. The data copying operation
The TXD and RXD of main access control machine connect to the
RXD and TXD of the same type of vice access control machine ,
TXD and RXD should be cross-linked,and then enter the copy
password on the main access control machine,The red and green
lights flash in the same time on two machines,until the tick
sound heard it finish data copying Copying password should
consult from agency or distributor (Note: Main access Machines
is machine with data, vice access control machine is required
writing data)
5. Access control mode conversion
Access mode: When GLED and GND connected to power, the green
light flashes, then disconnect GLED and GND , conversion is
finished when the tick sound is heard (the factory setting is
default setting as Access mode).
Reader mode (Wiegand 26 output): when D0 and GND connected to
power, the green light flashes, then disconnect D0 and GND ,
conversion is finished when the tick sound is heard Reader mode
(Wiegand 34 output): when D1 and GND connected to power, the
green light flashes, then disconnect D1 and GND , conversion
is finished when the tick sound is heard
12. set managed card( add and delete card)
Press
“
*
”
+
“
program code
”
+
“
#
”
+
“
9
”
+
“
swipe card
”
Note: swiping first one is to add card, second
time is to delete card. The function is for
easy access to add and delete user card. After
setting add and delete card, press
“
*
”
back
to the add and delete user card state again.
13. set open door general password
Press
“
*
”
+
“
program code
”
+
“
#
”
+
“
9
”
+
four digits password
”
Note: factory setting is 7890, cancel general
password by entering 0000
14. exit from programme state
Press
“
*
”
, after 10s and no operation, will
exit automatically
3. Jumper setting
(
1
)
J1.active and passive output setting.
When 1 and 2 connection, COM, CO,CN are on-off
signal output.. When 2 and 3 connection and
COM and GND are short out, then it is active
signal output.
(
2
)
J2. RESET reset setting. Initialize programming
code after electrify short j2
15. Tamper alarm turned on or off
Cancel the alarm: Enter the password to open the door in an
alarm state temporarily closed alarm
Close Alarm: Brush Remove the card three times to close the tamper alarm
Open alarm: Brush increase card three times to open the tamper alarm
Summary of Contents for NT-T10
Page 2: ...1 8000 user cards...