8

Set the Dispense Rate by choosing one of the preset default speeds. 

• Press the Single Barrel Select button. 

• Press F3 to select Rate.

• Select Medium

• Press the Cycle Start button once to return to the Home screen.

Note: The slower your Dispense Rate, the tighter your tolerance on repeatability.

• Select Pullback by pressing the Back button. 

• Use the (+) or (-) buttons to set the number of Pullback steps. 

Note: The maximum number of Pullback steps is 20,000. 

We recommend a minimum Pullback of 200 steps for low 
viscosity fluids. For thicker fluids set your Pullback to 300
steps or higher. During initial setup, adjust your Pullback in
sets of 50 steps at a time.

9

TIP

Pullback button

Dispense Rate

Pullback

3

Rate

Mod

F3/Rate

• Unscrew and remove the barrel retainer from the adapter. 

• Put a tip cap on the syringe barrel and hold barrel next to the 

flexible cable assembly. 

• From Manual mode (hand icon light on), advance the

plunger by pressing the Forward button, just until the
plunger reaches past the piston. 

• By hand, insert the plunger into the barrel, pressing it

into the piston. 

• Press the Pullback button to retract barrel, until there is just a small

gap between barrel and adapter. 

• Slide barrel retainer over the barrel and thread one turn onto the

adapter.

• Replace tip cap with dispense tip. Tighten barrel retainer.

• Still in Manual mode, press the foot pedal to purge dispense tip. Press

until fluid almost fills the tip and dispenses. Be sure not to overfill the
tip since this results in excess back pressure, which can cause oozing.

See the handout provided with your Ultimus IV
dispenser,“Syringe Barrel Attachment Guide,” for easy, step-by-
step instructions.

TIP

10

Plunger 

Barrel retainer 

Piston

Adapter 

Flexible cable assembly with syringe barrel 

Syringe barrel 

Attach Barrel/Purge Tip

Summary of Contents for Ultimus IV

Page 1: ...he forward or rear position on either side Remove barrel holder sleeve from holder Insert the 6 mm screw through the barrel holder and bracket and then into the top hole of the front mounting block Tighten screw to secure Insert barrel holder sleeve Part B Install Cable Guide Insert thumbscrew through both the cable guide mount and star washer and then into other mounting block π Position flex arm...

Page 2: ...red light is off TIP 1 Home Jog Hand icon Red Light OFF Program Red Light On Manual 2 Connect Power Foot Pedal 3 Connect the power cord provided to the back of the Ultimus IV and plug into your power source Connect the foot pedal provided to the back of the Ultimus IV Turn unit on On switch is located at the back of the unit An EFD 2800 screen will briefly appear before the Main Menu comes up Powe...

Page 3: ...the syringe barrel and hold barrel next to the flexible cable assembly From Manual mode hand icon light on advance the plunger by pressing the Forward button just until the plunger reaches past the piston By hand insert the plunger into the barrel pressing it into the piston Press the Pullback button to retract barrel until there is just a small gap between barrel and adapter Slide barrel retainer...

Page 4: ...els or cartridges to a temperature greater than 100 F 38 C Dispose of components according to local regulations after one time use Do not clean components with strong solvents e g MEK Acetone THF Cartridge retainer systems and barrel loaders should be cleaned with mild detergents only To prevent fluid waste use Nordson EFD SmoothFlowTM pistons For Nordson EFD LLC sales and service in over 30 count...

Reviews: