Maintenance
5-16
P/N 7146386A
E
2008 Nordson Corporation
VBN w/o Control System
Safety Valve Plate
Replacing O-rings
WARNING:
Hot! Risk of burns. Wear appropriate protective
clothing/equipment.
1. Heat the melter to operating temperature.
2. Empty tank.
3. Detach pump (Refer to section
Repair
.
4. Release the four fixing screws M8 from the safety valve plate and
remove plate.
5. Remove old O-rings and when present, the filter screen in the suction
hole.
6. Clean sealing surfaces on tank, safety valve plate and pump.
7. If there is one, clean filter screen and place in the groove again, or
replace with a new filter screen (P/N 394072).
8. Apply high temperature grease to O-rings
and sealing paste to sealing
surfaces. Attach O-rings.
9. Screw on safety valve plate.
10. Attach pump (Refer to section
Repair
).
11. Fill the tank.
Summary of Contents for VersaBlue 100H/100H
Page 46: ...Installation 3 14 P N 7146386A E 2008 Nordson Corporation VBN w o Control System...
Page 74: ...Maintenance 5 24 P N 7146386A E 2008 Nordson Corporation VBN w o Control System...
Page 94: ...Repair 7 14 P N 7146386A E 2008 Nordson Corporation VBN w o Control System...
Page 96: ...Parts 8 2 P N 7146386A E 2008 Nordson Corporation VBN w o Control System...