Troubleshooting
6‐15
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
No Line Speed Signal (Voltage / Current / Frequency)
Possible cause
Possible fault / troubleshooting
Corrective action
1.
Parent machine not
operating
-
Start up parent machine
2.
Polarity of line speed
voltage input is
reversed
-
Reverse polarity
3.
Encoder defective
-
Replace
Control Panel does not Function
Problem
Possible cause
Corrective action
1.
Does not start.
Control panel dark or
fault indications upon
startup
Memory board (CompactFlash) not
in place
Insert as described in section
Repair,
Replacing Memory Board
2.
Control panel dark or
bright
Brightness setting was changed
Use
to adjust
(Refer to section
Operation
)
3.
Control panel does
not function/react
Hardware defective
For spare parts numbers, refer to the
separate
Parts List
or to Appendix B,
depending on the melter
Control panel dirty
Clean as described in section
Maintenance / External Cleaning /
Control Panel
4.
No EtherNet
connection
Wrong/invalid IPC IP address set
Correct the IP address on the control
panel (Refer to section
Operation /
Control Panel - Overview - / V24
)
Refer to the section
Operation, Operation
via the IPC Webserver
Incorrect EtherNet cable plugged in
The LINK LED is lit when connected
properly
The ACT LED flashes when data is
transferred properly
Also refer to
LEDs of the IPC
in this
section
Summary of Contents for VersaBlue VA
Page 12: ...Table of Contents X P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 28: ...Safety Instructions 1 14 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 40: ...Introduction 2 12 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 62: ...Installation 3 22 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 74: ...Operation 4 12 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 142: ...Operation 4 80 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 174: ...Maintenance 5 26 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 204: ...Troubleshooting 6 30 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 234: ...Repair 7 30 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 248: ...Password A 4 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 272: ...Glossary D 16 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...