Operation
4‐23
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
Recommended Temperature Setpoints
The temperature setting is determined, among other things, by the
processing temperature prescribed by the material supplier.
CAUTION:
Nordson will grant no warranty and assume no liability for
damage resulting from incorrect temperature settings.
Grid
Up to 20 °C (36 °F) below prescribed processing temperature
Reservoir
Prescribed processing temperature
(Material quantity used <50 g/min: 0 to 10 °C (18 °F) below prescribed
processing temperature
Undertemperature value
(warning)
10 °C (18 °F) below set processing temperature
Air heater: approx. 10 °C (18 °F) below set processing temperature
Undertemperature value (fault) 15 °C (27 °F) below set processing temperature
Air heater: approx. 20 °C (36 °F) below set processing temperature
Overtemperature value
(warning)
10 °C (18 °F) above set processing temperature
Air heater: approx. 10 °C (18 °F) above set processing temperature
Overtemperature value (fault)
15 °C (27 °F) above set processing temperature
Air heater: approx. 20 °C (36 °F) above set processing temperature
Filling valve (option)
Prescribed processing temperature
*
Applicator (accessory)
Prescribed processing temperature(s)
*
Hose (accessory)
Prescribed processing temperature
*
* CAUTION:
The maximum operating temperature of the installed applicator and the other heated
components should be considered when setting temperatures on the melter control panel. Refer to
Control
Panel - Overview - / T1
.
Summary of Contents for VersaBlue VA
Page 12: ...Table of Contents X P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 28: ...Safety Instructions 1 14 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 40: ...Introduction 2 12 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 62: ...Installation 3 22 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 74: ...Operation 4 12 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 142: ...Operation 4 80 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 174: ...Maintenance 5 26 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 204: ...Troubleshooting 6 30 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 234: ...Repair 7 30 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 248: ...Password A 4 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 272: ...Glossary D 16 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...