220
GRID
Temperature setpoints
° C ° C
ALL HOSES
ALL GUNS
ALL
RESERVOIR
Hose 1
Gun 1
50
230
51
220
48
230
47
Fig. 4‐23
Keyboard symbol
Operation
4‐30
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
Temperature Parameters
Important
The temperature setting is determined, among other things, by the
processing temperature prescribed by the adhesive supplier.
Consider the maximum operating temperature of the installed applicator
and the other heated system components when setting temperatures.
Nordson will grant no warranty and assume no liability for damage
resulting from incorrect temperature settings.
Grid and reservoir: 175 °C (347 °F)
Hose 1 / Gun 1: Deactivated or 175 °C (347 °F), if activated
All other channels: Deactivated or 40 °C (104 °F), if activated
The temperature default settings are different beginning with software
version 6.47.035.
Grid and reservoir: 150 °C (302 °F)
Hose 1 / Gun 1: Deactivated or 150 °C (302 °F), if activated
All other channels: Deactivated or 40 °C (104 °F), if activated
Left temperature column (yellow): Actual values
NOTE:
If an actual value has a white background instead of yellow, the
channel is in standby.
Right temperature column (green): Setpoints
Display
Meaning
Only setpoints
Channel is deactivated
Only actual values
Channel is activated and in display mode
Setpoints and actual
values
Channel is activated and in control mode
ALL:
All temperature channels receive the same setpoint.
ALL HOSES / ALL GUNS:
All temperature channels in the respective group
receive the same setpoint.
NOTE:
If all of the temperature channels or all temperature channels of a
group do not have the same setpoint, a keyboard symbol is visible instead of
a setpoint. Touch symbol and set temperature with the input window.
Summary of Contents for VersaBlue VA
Page 12: ...Table of Contents X P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 28: ...Safety Instructions 1 14 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 40: ...Introduction 2 12 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 62: ...Installation 3 22 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 74: ...Operation 4 12 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 142: ...Operation 4 80 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 174: ...Maintenance 5 26 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 204: ...Troubleshooting 6 30 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 234: ...Repair 7 30 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 248: ...Password A 4 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 272: ...Glossary D 16 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...