Left
Right
Fig. 7‐39
Direction
Repair
7‐26
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
Calibrating
Prerequisites
Level sensor is installed, fastened mechanically and connected
electrically (observe color coding of sensor cable)
Tank empty (empty calibration: most sensitive setting, material irrelevant)
Operating voltage is applied (LED
Operating voltage
(1) lit).
Sensor Break
1. Turn potentiometer
A
(3) 20 revolutions to the left.
2. Turn potentiometer
P3
(2) to the right until the green LED
empty
(5) is off
and the red LED
full
(6) flashes.
NOTE:
Skip step 2. if the LED state is already known.
3. Turn potentiometer
P3
to the left to the switching point (green LED
empty
on, red LED
full
off).
4. From the switching point, turn one to two revolutions more to the left.
NOTE:
The closer the setting is to the switching point, the more precise is
the measurement. When the potentiometer
P3
is turned all the way to the left,
sensor break monitoring is deactivated.
5. Perform function test: Disconnect sensor cable; sensor break monitoring
is triggered (red LED
full
flashes).
Limit Switching Points
6. Turn potentiometer
A
to the right to the switching point (green LED
empty
off, red LED
full
on).
7. Turn back from switching point until the green LED
empty
is on.
Summary of Contents for VersaBlue VA
Page 12: ...Table of Contents X P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 28: ...Safety Instructions 1 14 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 40: ...Introduction 2 12 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 62: ...Installation 3 22 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 74: ...Operation 4 12 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 142: ...Operation 4 80 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 174: ...Maintenance 5 26 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 204: ...Troubleshooting 6 30 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 234: ...Repair 7 30 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 248: ...Password A 4 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 272: ...Glossary D 16 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...