Advanced Controller Configuration
6-34
Part 1126187_05
E
2021
Nordson Corporation
Applicator Settings(contd)
Setting
Default
Range/Option
Waveform - Optional
Dwell Time (t1)
0.2 ms
Minimum: 0.05 ms
Maximum: 0.5 ms
Closing Time (t2)
0.2 ms
Minimum: 0.2 ms
Maximum: 0.5 ms
One Complete Cycle (t3)
3 ms
Minimum: 3 ms
Maximum: 10 ms
Amplitude
100%
Minimum: 50%
Maximum: 100%
Cartridge Settings
Setting
Default
Range/Option
Ready Delay
1 minute
Minimum: 1 minute
Maximum: 60 minutes
Adhesive Lifetime Counter
300 minutes
Minimum: 25 minutes
Maximum: 960 minutes
Level Thresholds
Empty
0 ml
Minimum: 0 ml
Maximum: 1 ml
Low
5 ml
Minimum: 1 ml
Maximum: 20 ml
Controller Settings
Setting
Default
Range/Option
Service Interval: Seal Pack
40 Cycles/million
Minimum: 20 Cycles/million
Maximum: 100 Cycles/million
Service Interval: Needle Seat
100 Cycles/million
Minimum: 20 Cycles/million
Maximum: 100 Cycles/million
Password Protection
No Password Protection
High
Medium
Low
No Password Protection
Password Timeout
1 minute
Minimum: 1 minute
Maximum: 60 minutes