About the Touch Screen and User Interface
4-16
Part 1126187_05
E
2021
Nordson Corporation
Input Statuses
(contd)
2. Touch
View Input Status
.
3. Decide if you want to change the input type from PNP (Sourcing) - the
default to NPN (Sinking). Most supported robots are NPN.
Input Type
Description
PNP (Sourcing)
Select for signal sources that switch the input to 24V.
NPN (Sinking)
Select for signal sources that switch the input to 0V.
4. Decide if you want to drive the inputs with a relay or switch contact.
S
Disable this control when connecting to a robot that is sourcing (PNP)
24V to prevent power supply overloads.
S
You can switch this voltage through the relay contacts to drive the
inputs. Negative (-) Inputs must be set for Sourcing (PNP).
NOTE:
For signal sources that actively drive the signal to both 24V and 0V,
select PNP for the input type to maintain positive logic (24V input is the
active state). An NPN setting will provide negative logic (0V is the active
state).
Summary of Contents for Vulcan Jet