Input Status - Details
Pin Assignment
on I/O
Connector
Input
Description
19
Applicator Control from
parent machine (robot)
When active, causes the applicator to fire a waveform.
NOTE:
The Vulcan Jet Controller must be in a Ready/OK
state.
18
Fault Reset
When active, (energized state) pulse resets all alarms and
warnings. Equivalent to the panel reset function.
20
Standby Control
When active, causes the unit to go into Standby mode.
14
Robot Ready
When active, the robot is ready to make products.
22
Gun OFF time adjust
(analog)
0-10V analog input. Used to adjust the off time of the
applicator. 0 - 3V = 3 ms, 10V = 10 ms.
NOTE:
This input must be enabled from the user
interface before it is used.
17
Applicator Home
When active, indicates that the applicator is in the Home
position.
15
Robot Running
The robot is in motion when the following three outputs are
active:
S
Pressurized
S
Robot Ready
S
Glue On
16
Robot Fault
When active, a fault has been detected in the robot. The
Vulcan Jet Controller stops applying adhesive.
21
Pressurize cartridge
When active, the controller applies air pressure to the
cartridge and measures adhesive level.
9
Emergency Stop
When active, the controller stops applying adhesive and
switches Off the Master Heater control.
NOTE:
Verify the input type
before
changing it. If it is wrong, the inputs will
not work.
Summary of Contents for Vulcan Jet
Page 26: ...Description 2 8 Part 1126187_05 E 2021 Nordson Corporation This page intentionally left blank...
Page 162: ...Parts 9 4 Part 1126187_05 E 2021 Nordson Corporation Figure 9 2 Vulcan Jet applicator parts...
Page 163: ...Parts 9 5 Part 1126187_05 E 2021 Nordson Corporation Figure 9 3 Vulcan Jet applicator parts...
Page 171: ......
Page 172: ......