M4RL Series - Downflow Options
COMBUSTION
AIR
Rubber
Grommet
Plug
Plug
Option
7
Option
8
Option
9
VIEW -D-
VIEW -E-
VIEW -F-
See VIEW D for drain line positions
See VIEW E for drain line positions
See VIEW F for drain line positions
DOWNFLOW OPTIONS - 1 PIPE
Rubber
Grommet
Rubber
Grommet
Plug
Plug
Plug
Plug
FLUE PIPE
Rubber
Grommet
Plug
Plug
Option
10
Option
11
Option
12
See VIEW D for drain line positions
See VIEW E for drain line positions
See VIEW F for drain line positions
Rubber
Grommet
Rubber
Grommet
Plug
Plug
Plug
Plug
Flange
Flange
Flange
COMBUSTION AIR
FLUE PIPE
FLUE PIPE
FLUE PIPE
FLUE PIPE
FLUE PIPE
COMBUSTION
AIR
COMBUSTION
AIR
COMBUSTION AIR
COMBUSTION AIR
DOWNFLOW OPTIONS - 2 PIPE
Inline Drain
(Factory Supplied)
See NOTE 4
Collector Box Drain
(Factory Equipped)
See NOTE 2
Inline Drain
(Factory Supplied)
See NOTE 4
Collector Box Drain
(Factory Equipped)
See NOTE 2
Drain Line Attached
to PVC Trap
(Field Supplied)
Inline Drain
(Field Supplied)
See NOTES 2 & 3
Collector Box Drain
(Factory Equipped)
See NOTE 2
X
See
NOTE 5
X
See
NOTE 5
PVC
Tee
PVC
Trap
X
See
NOTE 5
X
See
NOTE 5
PVC
Tee
PVC
Trap
) for optional PVC Tee configurations and drainage options.
2. Drain lines must be trapped with a J-Trap or field supplied loop. Traps may be positioned inside or outside
the cabinet. All drain lines must be routed externally from the cabinet.
3. Inline drain is required only if “X” is greater than 6 feet.
4. Tubing needs to be cut to length and attached during unit installation.
5. Horizontal piping from inducer to flue pipe must be sloped 1/4” per foot to ensure drainage to PVC trap.