Do not place products so that they protrude over the front edge of the shelf or obstruct the
inlet grid.
An unobstructed space of at least 20 mm must be left between the shelves and
the top plate of the cabinet. Products must not be placed in front of the inlet and
outlet grids and must not protrude over the front edges of the shelves. Improper
loading of the cabinet will disrupt the air flow and raise the temperature of products
in the cabinet.
See
figures 2 and 3 on the inside cover
.
• Do not place goods on top of the cabinet.
The cabinet is not designed to cool down products but to maintain them at the
temperature at which they are placed in the cabinet. Food products warmer than
the specified temperature should not be placed in the cabinet.
NOTE
4.3. Setting operating thermostat
The operating thermostat for the cabinet is located in the terminal box inside the machinery
compartments. The lid to the machinery compartment is fixed with a spring. The thermostat is
preset to the correct temperature at the factory.
4.4. NRC-100 control device
NRC-100 is a cabinet controller that automates cabinet defrosting by means of a thermostat and
temperature sensor.
4.4.1. Display messages
In normal status, the display shows cabinet temperature.
Defrosting signals
Waiting for other cabinets
when synchronising defrost.
Pull down. Cooling until
expected temperature is
reached.
Defrosting under way.
Probe failure alarm signals
Cabinet temperature probe
failure. Contact service.
Evaporator probe failure.
Contact service.
Thermostat probe failure. Contact
service.
Safety switch probe failure.
Contact service.
Safety switch probe failure. Contact
service.